CaLan® 3010H+ DOCSIS 3.X/4.0

Sweep System for DOCSIS 3.1 and 4.0

The CaLan 3010H+ Sweep System is designed for prequalification, installation, and maintenance of DOCSIS 3.1 and 4.0 networks. The unit consists of a high performance, 1.8 GHz Transmitter and a low noise, 204 MHz Receiver, capable of sweeping the entire Forward and Return path respectively.

...

  • High resolution true non-interfering 1.8 GHz downstream sweep system with Manual and Automatic Gain & Slope Offsets
  • 1U 19 inch Rackmount form factor, saving critical rack space in the Headend
  • Fast and accurate Sweep for network maintenance
  • Channel and Spectrum Scans modes
  • Full integration with VeSion® system, supporting centralized control for sweep profiles and data collection, making it ideal for unmanned Headends
  • Compatible with CX380s series and CM series field test sets
  • Works with the AT3000 RF Switch Multiplexer
  • Combined with In Service Sweep for a complete Forward Path Sweep, up to 1.8 GHz
  • Return Path Sweep up to 204 MHz

  • DigiSweep Fast Sweep technology helps maintenance technicians perform their task faster and easier then other solutions
  • Non-Interfering Downstream Sweep for Analog and Digital Channels
  • Dual Path mode eliminates the need for a separate Forward Sweep and Return Sweep instruments
  • Higher resolution sweep identifies problems other sweep systems miss
  • Automatic recovery following power outages
Sweep Source (Forward)
Output Frequency Range 5 MHz to 1800 MHz
Output Level Range +10 dBmV to +50 dBmV
Level Accuracy ±1.5 dB
Source Output Return Loss >10 dB
Sweep Pulse Frequency Accuracy <30 kHz
(5 MHz to 1800 MHz)
Sweep Receiver (Return)
Input Frequency Range 5 MHz to 204 MHz
Input Level Range -10 dBmV to +15 dBmV
Input Frequency Resolution 10 kHz
Input Return Loss >10 dB
SNR (Avg) Comm. Ch. Detection 25 dB Min.
Spurious <-45 dBc
DC Blocking 200 VDC
Data Transmission Pilot
Range 5 MHz to 1800 MHz
Data Carrier Modulation Bandwidth <300 kHz
General Specifications
Size (H x W x D) 1.75” x 19” x 11.75” - 1 RU (Rack Units) high
Weight 8 lbs (3.628 kg)
Operating Temperature 5˚C to +40˚C
Storage Temperature -40˚C to +70˚C
Power
AC Adaptor Input: 100-240 VAC, 50-60 Hz
Output: 15 VDC, 4.6A
48 VDC Power Option DC Input range: -40 VDC to -60 VDC
Max current: 2A at -48 VDC
Brochures
Release Notes
Software

Attention: DO NOT downgrade the software version currently installed in your test platform or module, unless specifically instructed by a VeEX Customer Care/Support agent. Your new test set may have been shipped with a newer version. For software upgrades, please check the current version(s) on your test set to confirm that the software posted here is a newer version and carefully read the Release Notes for the recommended platform versions.